Seismic energy assessment of buildings with tuned vibration absorbers
- verfasst von
- Said Elias
- Abstract
Seismic analysis and energy assessment of building installed with distributed tuned vibration absorbers (d-TVAs) are presented. The performance of d-TVAs is compared with single tuned vibration absorber (STVA) installed at the top of the building. The placements of the d-TVAs are based on the modal properties of the uncontrolled and controlled buildings. The governing equations of motion of the building with the STVA and d-TVAs are solved by employing Newmark's integration method. Various energies under earthquake ground excitations are computed to study the effectiveness of using the STVA and d-TVAs. It is concluded that the use of the d-TVAs is the most competent because it effectively dissipates the seismic energy, and they are convenient to install requiring reduced space, as are placed at various floors.
- Externe Organisation(en)
-
University of Iceland
Universität Herat
- Typ
- Artikel
- Journal
- Shock and vibration
- Band
- 2018
- ISSN
- 1070-9622
- Publikationsdatum
- 2018
- Publikationsstatus
- Veröffentlicht
- Peer-reviewed
- Ja
- ASJC Scopus Sachgebiete
- Tief- und Ingenieurbau, Physik der kondensierten Materie, Geotechnik und Ingenieurgeologie, Werkstoffmechanik, Maschinenbau
- Elektronische Version(en)
-
https://doi.org/10.1155/2018/2051687 (Zugang:
Offen)